A Comparative Study of Fecal Occult Blood Tests For Early Detection of Gastrointestinal Pathology
Document Type
Article
Publication Date
5-1990
Abstract
he question of what the most accurate and efficient fecal occult blood testing method is for the early detection of pathological gastrointestinal tract bleeding continues to be intensely debated. In this prospective study, the following five uniquely different slide tests were investigated in 120 patients who underwent gastrointestinal tract investigation: (1) a combination monoclonal antibody guaiac test (Monohaem); (2) an immunologic assay, enzyme-linked immunosorbent assay, with (3) a highly sensitive guaiac test (Fecatwin S/Feca enzyme immunoassay), (4) a popular guaiac test (Coloscreen III) (comparable with Hemoccult II), and (5) Coloscreen III/VPI (ie, with vegetable peroxidase) inhibitor. Computerized data show efficiency values for detection of fecal occult blood by Coloscreen III-Fecatwin S-Monohaem combined, 93%; Coloscreen III-Monohaem combined, 91%; Monohaem, 87%; Coloscreen III/VPI, 82%; Coloscreen III, 79 percent; enzyme-linked immunosorbent assay, 77%; and Fecatwin S, 68%. Results of sensitivity, specificity, false-positive and false-negative test results, tests' predictive value, simplicity, and costs of tests in this clinically based study suggests that the concomitant use of the monoclonal, monospecific test for human hemoglobin and an appropriately sensitive guaiac test is a potentially valuable approach to mass screening and early detection of occult bleeding gastrointestinal tract pathology, including colorectal cancer.
Repository Citation
Stelling, H. P.,
Maimon, H. N.,
Smith, R. A.,
Haddy, R. I.,
& Markert, R. J.
(1990). A Comparative Study of Fecal Occult Blood Tests For Early Detection of Gastrointestinal Pathology. Archives of Internal Medicine, 150 (5), 1001-1005.
https://corescholar.libraries.wright.edu/internal_medicine/22
DOI
10.1001/archinte.1990.00390170055013